Thermocouple temperature signal converted to RS-485 WJ127
  • Model: WJ127
  • In Stock: 9999

Thermocouple temperature signal converted to RS-485 WJ127

$18.99
Thermocouple temperature signal converted to RS-485, Modbus data acquisition module WJ127 Product features: One thermocouple signal acquisition isolation conversion RS-485 output Using a 12 bit AD converter, the measurement accuracy is better than 0.1% Isolation and withstand voltage 1000VDC...

Add to Cart:
Min:  2
  • Shipping Weight: 0.3g
  • This product was added to our catalog on Wednesday 03 July, 2024.
Description

Thermocouple temperature signal converted to RS-485, Modbus data acquisition module WJ127
Product features:
One thermocouple signal acquisition isolation conversion RS-485 output
Using a 12 bit AD converter, the measurement accuracy is better than 0.1%
Isolation and withstand voltage 1000VDC between signal inputs/outputs
Wide power supply range: 8~32VDC
K/J/T/E/R/S/B/N type thermocouple input
High reliability, convenient programming, and easy application
Standard DIN35 rail installation for convenient centralized wiring
User programmable module address, baud rate, etc
Supports Modbus RTU communication protocol and automatic recognition protocol
Industrial flame-retardant housing, RS485 port surge protection
Low cost, small volume modular design
Typical applications:
Temperature signal measurement, monitoring, and control
RS-485 remote I/O, data collection
Intelligent building control, security engineering and other application systems
RS-485 bus industrial automation control system
Industrial site signal isolation and long-distance transmission
Equipment operation monitoring
Measurement of sensor signals
Acquisition and recording of industrial site data
Development of medical and industrial control products
Various types of thermocouple signal acquisition
Product Overview:
The WJ127 product realizes signal acquisition between sensors and the host to detect analog signals. The WJ27 series products can be applied to RS-485 bus engineering
Industrial automation control system, measurement of K/J/T/E/R/S/B/N type thermocouple signals, as well as industrial site signal isolation and long-distance transmission, etc.
The products include power isolation, signal isolation, linearization, A/D conversion, and RS-485 serial communication. Each serial port can connect up to 255 W1J25 series
Module, communication mode adopts ASCII code communication protocol or MODBUS RTU communication protocol, address and baud rate can be set by code, and can communicate with other manufacturers
The control module is mounted on the same RS-485 bus for easy computer programming.

The WJ127 series products are intelligent monitoring and control systems based on microcontrollers, with all user set calibration values, addresses, baud rates, and data formats,
Parity check and other configuration information are stored in the non-volatile memory EEPROM.
The WJ127 series products are designed and manufactured according to industrial standards, with isolation between signal inputs/outputs, capable of withstanding 1000VDC isolation voltage, and anti-interference ability
Strong strength and high reliability. Working temperature range -45 ℃ to+85 ℃.

Function Introduction:
The WJ127 signal isolation acquisition module can be used to measure one temperature signal.
1. Temperature signal input
12 bit acquisition accuracy, 1 thermocouple temperature signal input. All signal input ranges have been calibrated before the product leaves the factory. When in use, users can also
Easy self programming calibration.
2. Communication protocol
Communication interface: 1 standard RS-485 communication interface.
Communication protocol: Supports two protocols, the character protocol defined by the command set and the MODBUS RTU communication protocol. The module automatically recognizes the communication protocol,
Can achieve network communication with multiple brands of PLC, RTU or computer monitoring systems.
Data format: 10 digits. 1 start bit, 8 data bits, 1 stop bit, no checksum.
The communication address (0-255) and baud rate (2400, 4800, 9600, 19200, 38400, 57600, 115200bps) can be set; Communication network
The longest distance of the network can reach 1200 meters and is connected through twisted pair shielded cables.
High anti-interference design of communication interface, ± 15KV ESD protection, communication response time less than 100mS. 3. Anti-interference
Parity can be set as needed. There are transient suppression diodes inside the module, which can effectively suppress various surge pulses and protect the module
Digital filtering can also effectively suppress power frequency interference from the power grid.

Product manual:https://www.wayjun.cn/d/

Reviews (0)
There are currently no product reviews.
Back to Top